Features
DV SERIES
Double-filtered pilot-flow design for maximum
reliability
Balanced-pressure diaphragm for long life
External bleed to manually flush system of dirt
and debris during installation and system start
up
Internal bleed for spray-free manual operation
Energy efficient, low-power encapsulated solenoid
with captured plunger and
90-mesh (200 micron) solenoid filter
Buna-N diaphragm with self-cleaning
90-mesh (200 micron) pilot water filter and captive
spring
Operates in low-flow and Xerigation
ฎ applications
when the RBY filter is
installed upstream
1
1⁄4" (3,2 cm) stainless steel phillips head screws
Accepts latching solenoid for use with Rain Bird
battery-operated controllers
Available as:
3⁄4" (20/27) and 1" (26/34) standard in-line configuration
1" (26/34) Slip-by-Slip (SS) configuration for
low cost, solvent-weld installations
1" (26/34) Angle (A) configuration for flexible
installations especially when submains are
deep
1" (26/34) Male-by-Male (MM) male thread
configuration for quick and easy manifolding
1" (26/34) Male-by-Barb (MB) and 1" Male-by-
1
1/4" Barb male thread inlet by barb outlet configuration
for installation with poly pipe
1" Union-by-Union (UU) female union thread
configuration for quick and easy manifolding
1" Union-by-Barb (UB) female union thread
inlet by barb outlet configuration for quick and
easy manifolding for use with poly pipe
DVF SERIES
Incorporates all features of DV Series valves
Unique, easy-to-turn pressure-assisted flow
control mechanism
ASVF SERIES
Combination reliable DVF valve and atmospheric
backflow preventer in one unit
Incorporates all features of DVF Series valves,
plus meets I.A.P.M.O. and A.S.S.E. listing specifications,
City of Los Angeles and Canadian
Standards Association listings approved
Must be installed at least 6" (15,2 cm) above the
highest point of water in the sprinkler pipe it
serves
No valve can be located downstream of the antisiphon
valve
Consult local codes
Operating Range
Pressure: 15 to 150 psi (1,0 to 10,4 bar)
075-DV/ASVF Flow: 0.2 to 22 gpm (0,05 to 5,0
m
3/h; 0,01 to 1,39 l/s); for flows below 3 gpm (0,75
m
3/h; 0,21 l/s) or any Xerigation application, use
RBY-075-200MX filter installed upstream
100-DV/DVF/ASVF (non-union) Flow: 0.2 to 40
gpm (0,05 to 9,08 m
3/h; 0,01 to 2,52 l/s); for flows
below 3 gpm (0,75 m
3/h; 0,21 l/s) or any
Xerigation application, use RBY-100-200MX filter
installed upstream
100-DV/DVF (union) Flow: 0.2 to 20 gpm (0,05 to
4,54 m
3/h, 0,01 to 1,26 l/s); for flows below 3 gpm
(0,75 m
3/h; 0,21 l/s) or any Xerigation application,
use RBY-100-200MX filter installed upstream
Temperature: Up to 110ฐ F (43ฐ C)
Ambient air temperature up to 125ฐ F (52ฐ C)
Electrical Specifications
24 VAC 50/60 Hz (cycles per second)
solenoid power requirement
0.30 A (7.2 VA) inrush current
0.23 A (5.5 VA) holding current
Solenoid coil resistance: 38 Ohms
Dimensions
DV SERIES
Height: 4
1⁄2" (11,4 cm)
(Angle) 5
1⁄2" (14 cm)
Length: 4
3⁄8" (11,1 cm) (MB) 53⁄4" (14,6 cm)
(Angle) 3
3⁄4" (9,5 cm) (UU) 57⁄8" (14,9 cm)
(MM) 5
3⁄8" (13,6 cm) (UB) 6" (15,2 cm)
Width: 3
1⁄3" (8,4 cm)
DVF SERIES
Height: 5
3⁄5" (14,2 cm)
(Angle) 5
1⁄2" (14 cm)
Length: 4
3⁄8" (11,1 cm) (MB) 53⁄4" (14,6 cm)
(Angle) 3
3⁄4" (9,5 cm) (UU) 57⁄8" (14,9 cm)
(MM) 5
3⁄8" (13,6 cm) (UB) 6" (15,2 cm)
Width: 3
1⁄3" (8,4 cm)
ASVF SERIES
Height: 6
1⁄4" (15,8 cm)
Length: 6
1⁄10" (15,5 cm)
Width: 3
1⁄5" (8,1 cm)
Models
075-DV:
3⁄4" (20/27) 100-DV-MM: 1" (26/34)*
100-DV: 1" (26/34)* 100-DV-MB: 1" (26/34)
100-DV-SS: 1" (26/34) 100-DV-UU: 1" (26/34)*
100-DV-A: 1" (26/34)* 100-DV-UB: 1" (26/34)
125-DV-MB: 1" (26/34)M x 1
1/4"(33/42)B
100-DVF: 1" (26/34)* 100-DVF-MB: 1" (26/34)
100-DVF-SS: 1" (26/34) 100-DVF-UU: 1" (26/34)*
100-DVF-A: 1" (26/34) 100-DVF-UB: 1" (26/34)
100-DVF-MM: 1" (26/34)*
125-DVF-MB: 1" (26/34)M x 1
1/4"(33/42)B
075-ASVF:
3⁄4" (20/27)
100-ASVF: 1" (26/34)
*Available with BSP threads