Features
DV SERIES
• Double-filtered pilot-flow design for maximum
reliability
• Balanced-pressure diaphragm for long life
• External bleed to manually flush system of
dirt and debris during installation and system
start up
• Internal bleed for spray-free manual operation
• Energy efficient, low-power encapsulated
solenoid with captured plunger and
90-mesh (200 micron) solenoid filter
• Buna-N diaphragm with self-cleaning
90-mesh (200 micron) pilot water filter and
captive spring
• Operates in low-flow and Xerigation
® applications
when the RBY filter is
installed upstream
• 1
1⁄4" (3,2 cm) stainless steel phillips head
screws
• Accepts latching solenoid for use with Rain
Bird battery-operated controllers
• Available as:
•
3⁄4" (20/27) and 1" (26/34) standard inline
configuration
• 1" (26/34) Slip-by-Slip (SS) configuration
for low cost, solvent-weld installations
• 1" (26/34) Angle (A) configuration for
flexible installations especially when submains
are deep
• 1" (26/34) Male-by-Male (MM) male
thread configuration for quick and easy
manifolding
• 1" (26/34) Male-by-Barb (MB) and 1"
Male-by-1
1/4" Barb male thread inlet by
barb outlet configuration for installation
with poly pipe
DVF SERIES
• Incorporates all features of DV Series valves,
plus:
• Unique, easy-to-turn pressure-assisted flow
control mechanism
ASVF SERIES
• Combination reliable DVF valve and atmospheric
backflow preventer in one unit
• Incorporates all features of DVF Series
valves, plus meets I.A.P.M.O. and A.S.S.E.
listing specifications, City of Los Angeles
and Canadian Standards Association listings
approved
• Must be installed at least 6" (15,2 cm) above
the highest point of water in the sprinkler
pipe it serves
• No valve can be located downstream of the
anti-siphon valve
• Consult local codes
Operating Range
• Pressure: 15 to 150 PSI (1,0 to 10,4 Bars)
• 075 DV Flow: 0.2 to 22 GPM (0,05 to 5,0
m
3/h; 0,01 to 1,39 l/s); for flows below 3
GPM (0,75 m
3/h; 0,21 l/s) or any Xerigation
application, use RBY-075-200MX filter
installed upstream
• 100-DV Flow: 0.2 to 40 GPM (0,05 to 9,08
m
3/h; 0,01 to 2,52 l/s); for flows below 3
GPM (0,75 m
3/h; 0,21 l/s) or any Xerigation
application, use RBY-100-200MX filter
installed upstream
• Temperature: Up to 110° F (43° C)
• Ambient air temperature up to 125° F (52° C)
Electrical Specifications
• 24 VAC 50/60 cycle solenoid power requirement
• 0.30 A (7.2 VA) inrush current
• 0.19 A (4.6 VA) holding current
• Solenoid coil resistance: 54 Ohms
Dimensions
DV SERIES
• Height: 4
1⁄2" (11,4 cm)
(Angle) 5
1⁄2" (14 cm)
• Length: 4
3⁄8" (11,1 cm)
(Angle) 3
3⁄4" (9,5 cm)
(MM) 5
3⁄8" (13,6 cm)
(MB) 5
3⁄4" (14,6 cm)
• Width: 3
1⁄3" (8,4 cm)
DVF SERIES
• Height: 5
3⁄5" (14,2 cm)
(Angle) 5
1⁄2" (14 cm)
• Length: 4
3⁄8" (11,1 cm)
(Angle) 3
3⁄4" (9,5 cm)
(MM) 5
3⁄8" (13,6 cm)
(MB) 5
3⁄4" (14,6 cm)
• Width: 3
1⁄3" (8,4 cm)
ASVF SERIES
• Height: 6
1⁄4" (15,8 cm)
• Length: 6
1⁄10" (15,5 cm)
• Width: 3
1⁄5" (8,1 cm)
MODELS
• 075-DV:
3⁄4" (20/27)
• 100-DV: 1" (26/34)*
• 100-DV-SS: 1" (26/34)
• 100-DV-A: 1" (26/34)*
• 100-DV-MM: 1" (26/34)*
• 100-DV-MB: 1" (26/34)
• 125-DV-MB: 1" (26/34)M x 1
1/4"(33/42)B
• 100-DVF: 1" (26/34)*
• 100-DVF-SS: 1" (26/34)
• 100-DVF-A: 1" (26/34)
• 100-DVF-MM: 1" (26/34)*
• 100-DVF-MB: 1" (26/34)
• 125-DVF-MB: 1" (26/34)M x 1
1/4"(33/42)B
• 075-ASVF:
3⁄4" (20/27)
• 100-ASVF: 1" (26/34)
*Available with BSP threads