Whether the job calls for a globe or angle
valve, PGA Series valves are the right choice.
Loaded with features, these heavy-duty PVC
valves are economical, easy to install and built
to withstand constant 150 psi (10,35 bar) pressure
and 2 to 150 gpm (0,45 to 34,05 m
3/h;
7,8 to 568 l/m) flows.
The PGA Series from Rain Bird built to last
and last!
Features
Globe and angle configuration for flexibility
in design and installation.
Rugged PVC construction
Filtered pilot flow to resist debris and
clogging of solenoid ports.
Slow closing to prevent water hammer and
subsequent system damage.
Manual internal bleed operates the valve
without allowing water into the valve box.
One-piece solenoid design with captured
plunger and spring for easy servicing.
Prevents loss of parts during field service.
Non-rising flow control handle adjusts
water flows as needed.
Normally closed, forward flow design.
Options (order separately)
Accommodates optional, field installed
PRS-D pressure regulating module.
Optional purple flow control handle for
easy identification of non-potable water
system.
- PGA-NP-HAN (1 and 1
1⁄2)
- PGA-NP-HAN2 (2)
Accepts latching solenoid for use with Rain
Bird battery-operated controllers up to 150
psi (10,35 bar).
Operating Range
Pressure: 15 to 150 psi (1,04 to 10,35 bar)
Flow: 2 150 gpm (0,45 to 34,05 m
3/h;
7,8 to 568 l/m)
Flow with PRS-D: 5 150 gpm (1,14 to 34,05
m
3/h; 19,2 to 568 l/m)
Water Temperature: up to 110° F (43° C)
Ambient Temperature: up to 125° F (52° C)
Electrical Specifications
Power: 24 VAC 50/60 Hz (cycles/sec)
solenoid
Inrush current: 0.41 A (9.84 VA) at 60 Hz
Holding current: 0.28 A (6.72 VA) at 60 Hz
Coil resistance: 30-39 Ohms
Models
100PGA 1 (26/34)
150PGA 1
1⁄2 (40/49)
200PGA 2 (50/60)
BSP threads available; specify when ordering.
Notes
1) Loss values are with flow control fully open.
2) PRS-D module recommended for all flow ranges.
Recommendations
1) Rain Bird recommends flow rates in the supply line not to exceed 7.5 ft./sec.
(2,29 m/s) in order to reduce the effects of water hammer.
2) For flows below 5 gpm (1,14 m3⁄h; 19,21 l/m), Rain Bird recommends use of
upstream filtration to prevent debris from collecting below the diaphragm.
3) For flows below 10 gpm (2,27 m3⁄h; 37,8 l/m) Rain Bird recommends the
flow control stem be turned down two full turns from the fully open position.
How to Specify/Order
100 - PGA - PRS-D
Size Model Optional Feature
100: 1 PGA PRS-D: pressure
150: 1
1⁄2 regulating module
200: 2
Note: Valve and PRS-D module must be ordered separately.
Flow F low 100- 100- 150- 150- 200- 200-
m3⁄h I/m PGA PGA PGA PGA PGA PGA
Globe Angle Globe Angle Globe Angle
2,5cm 2,5cm 3,8cm 3,8cm 5,1cm 5,1cm
0,23 3,8 0,35 0,30 - - - -
0,6 10 0,36 0,32 - - - -
1,2 20 0,38 0,35 - - - -
3 50 0,41 0,38 - - - -
6 100 0,43 0,38 0,10 0,07 - -
9 150 0,48 0,51 0,22 0,14 0,08 0,07
12 200 - - 0,38 0,23 0,12 0,07
15 250 - - 0,61 0,36 0,17 0,10
18 300 - - 0,86 0,51 0,24 0,13
21 350 - - 1,16 0,70 0,33 0,18
24 400 - - - - 0,43 0,23
27 450 - - - - 0,54 0,30
30 500 - - - - 0,66 0,36
34 568 - - - - 0,83 0,45
PGA Series Valve Pressure Loss (bar)
Flow 1 00- 100- 150- 150- 200- 200-
gpm PGA PGA PGA PGA PGA PGA
Globe Angle Globe Angle Globe Angle
1" 1" 1
1 ⁄2" 11 ⁄2" 2" 2"
1 5.1 4.3 - - - -
5 5.5 5.0 - - - -
10 5.9 5.5 - - - -
20 6.0 5.6 - - - -
30 6.4 5.5 1.9 1.3 - -
40 7.0 7.5 3.2 2.0 1.2 1.0
50 - - 4.8 3.0 1.5 0.9
75 - - 11.1 6.5 3.0 1.7
100 - - 19.2 11.7 5.5 3.0
125 - - - - 8.6 4.8
150 - - - - 12.0 6.5
PGA Series Valve Pressure Loss (psi)
Water Temp. Continuous Pressure
73˚ F (23˚ C) 150 psi (10,40 bar)
80˚ F (27˚ C) 132 psi (9,10 bar)
90˚ F (32˚ C) 112 psi (7,70 bar)
100˚ F (38˚ C) 93 psi (6,40 bar)
110˚ F (43˚ C) 75 psi (5,20 bar)
PGA Series Temperature Rating
Dimensions
Size Height Length Width
100PGA 7
1⁄4 (18,4 cm) 51⁄2 (14,0 cm) 31⁄4 (8,3 cm)
150PGA 8 (20,3 cm) 6
3⁄4 (17,2 cm) 31⁄2 (8,9 cm)
200PGA 10 (25,4 cm) 7
3⁄4 (19,7 cm) 5 (12,7 cm)
Note: The PRS-D option adds 2 (5,1 cm) to valve height.