Pressure surges? Effluent water? Clogging
debris? No problem. PEB and PESB Series
valves offer long life and efficient, trouble-free
performanceeven under harsh conditions.
Constructed of heavy-duty, glass-filled nylon,
these valves resist clogging. And the PESB
model features a patented scrubber to actively
fight dirt, debris and particles.
Features
Body constructed of durable glass-filled
nylon for long life and heavy-duty performance
at 200 psi (13,80 bar) pressure.
Stainless steel studs molded into the body.
Bonnet can be attached and removed more
easily without damaging threads.
One-piece solenoid design with captured
plunger and spring for easy servicing. Prevents
loss of parts during field service.
External bleed protects the solenoid ports
from debris when system is flushed.
Internal bleed operates the valve without
allowing water into the valve box; allows
pressure regulator to be adjusted without
turning on the valve at the controller first.
Low flow operating capability (0.25 gpm;
0,06 m
3/h; 1,2 l/m) for a wide range of applications.
For flows below 5 gpm (1,14 m
3⁄h;
19,2 l/m) or any Xerigationฎ application,
install Rain Bird Y filter upstream.
Slow closing to prevent water hammer and
subsequent system damage.
PESB only: Scrubber scrapes its stainless
steel screen clean to break down grit and
plant material. Prevents debris build-up and
clogging.
Options (order separately)
Accommodates optional, field installed
PRS-D pressure regulating module to ensure
optimum sprinkler performance.
Optional purple flow control handles for
non-potable water applications
- PEB-NP-HAN1(1)
- PEB-NP-HAN2 (1
1⁄2 and 2)
Accepts latching solenoid for use with
Rain Bird battery-operated controllers up to
150 psi (10,35 bar).
Operating Range
Pressure: 20 to 200 psi (1,38 to 13,80 bar)
Flow: 0.25 to 200 gpm (0,06 to 45,40 m
3⁄h;
1,2 to 757 l/m)
Flow with PRS-D: 5 to 200 gpm
(1,14 to 45,40 m
3⁄h; 19,2 to 757 l/m)
Temperature: up to 150ฐ F (66ฐ C)
Electrical Specifications
Power: 24 VAC 50/60 Hz (cycles/sec)
solenoid
Inrush current: 0.41 A (9.84 VA) at 60 Hz
Holding current: 0.28 A (6.72 VA) at 60 Hz
Coil resistance: 30-39 Ohms
Models
100PEB and 100PESB 1 (26/34)
150PEB and 150PESB 1
1⁄2 (40/49)
200PEB and 200PESB 2 (50/60)
BSP threads available, specify when ordering.
Notes
1) Loss values are with flow control fully open.
2) PRS-D module recommended for all flow ranges.
Recommendations
1) Rain Bird recommends flow rates in the supply line not to exceed 7.5 ft./sec.
(2,29 m/s) in order to reduce the effects of water hammer.
2) For flows below 5 gpm (1,14 m3⁄h; 19,21 l/m), Rain Bird recommends use of
upstream filtration to prevent debris from collecting below the diaphragm.
3) For flows below 10 gpm (2,27 m3⁄h; 37,8 l/m) Rain Bird recommends the
flow control stem be turned down two full turns from the fully open position.
How to Specify/Order
100 - PEB - PRS-D
Size Model Optional Feature
100: 1 PEB PRS-D: pressure
150: 1
1⁄2 PESB: scrubber regulating module
200: 2 model
Note: Valve and PRS-D module must be ordered separately.
Flow 100-PEB 150-PEB 200-PEB
gpm 1" 1
1⁄2" 2"
0.25 0.8 - -
0.5 1.0 - -
1 1.3 - -
5 1.7 - -
10 1.8 - -
20 2.9 3.9 -
30 5.6 3.6 -
40 10.0 3.5 -
50 15.6 3.6 4.8
75 - 5.4 4.5
100 - 9.6 5.2
125 - 14.6 8.2
150 - 21.2 11.8
175 - - 15.5
200 - - 19.5
PEB and PESB Series Valve Pressure Loss (psi)
Flow Flow 100-PEB 150-PEB 200-PEB
m3⁄ h l/m 2,5 cm 3,8 cm 5,1 cm
0,06 1 0,06 - -
0,3 5 0,09 - -
0,6 10 0,10 - -
1,2 20 0,12 - -
3 50 0,15 - -
6 100 0,32 0,26 -
9 150 0,68 0,24 -
12 200 - 0,26 0,33
15 250 - 0,33 0,32
18 300 - 0,42 0,32
21 350 - 0,57 0,34
24 400 - 0,74 0,41
27 450 - 0,92 0,51
30 500 - 1,14 0,64
33 550 - 1,38 0,77
36 600 - - 0,90
39 650 - - 1,04
42 700 - - 1,18
45 757 - - 1,34
PEB and PESB Series Valve Pressure Loss (bar)
Dimensions
Size Height Length Width
100 6
1⁄2 (16,5 cm) 4 (10,2 cm) 4 (10,2 cm)
150 8 (20,3 cm) 6 (15,2 cm) 6 (15,2 cm)